All Tools

Remove Magnetic Debris Buildup

It is possible for dust, soil, and other debris to magnetically attract to a tool’s magnets and build up over time. This debris can prevent the tool from correctly mounting to the UTM.

Every three months

Inspect the tool’s magnets for debris. If any is found, use your fingers or a brush to remove it. Remove debris immediately if a tool is dropped into the soil

Seeder

Remove internal debris buildup

It is possible for dust, soil, and other debris to become stuck inside of the plastic seed injector tip. This can cause a loss of seed suction power and prevent the seed injector from working reliably.

Every three months

Wash out the inside of the seed injector tip by running warm water through the seed injector.

Watering Nozzle

Dissolve mineral buildup

It is possible - depending on your water source - for the watering nozzle to slowly become clogged with mineral buildup and other deposits. This can prevent FarmBot from watering the correct amount for each plant and also cause uneven spray.

Every 6 months

Inspect the watering nozzle for any deposits or unusual spray patterns. To remove buildup, soak your watering nozzle in a bowl of distilled white vinegar and hot water for a few hours. This should dissolve most things. If needed, use a toothpick, thumbtack, or paperclip to remove any debris left in the nozzle holes.